Fluid Leak Detection System
The fluid leakage in the building such as data centre or commander room can stop all electrical and electronical equipments and the relevant safety systems from appropriate operation.
Furthermore it can cause secondary losses such as environmental pollution, fire, explosion and/or casualties.
LEAKBAN leak detection cable system can detect various types of leakage from pipes and equipment. Furthermore, it pinpoints the position where the leakage occured with high accuracy.
LEAKBAN LDS is an essential part for safety and preventive operation system in industrial society.
Features of LEAKBAN System
- Conform with EMI/EMC requirements
- Sensing cable can be connected up to 1km
- Fast response ( default 8 seconds )
- Leak point positioning with ± 1m / 1,000m
- Sensing wires sitting in deep groove makes it fault-free
- Durable and flexible
- Reusable
- Chemical and abrasion resistance
- Standard supply length : 3m, 7.5m, and 15m
LDS System
Network System
LEAKBAN LBMM-100, main display module is connected with LBSM, the submodule via RS485 and monitors the status of all the linked submodules and sensing cables. Specially when it detects the leakage, it automatically triggers an auditory and visual alarm for the recognition from the distance.
Max. 32 submodules can be linked with LBMM-100 via RS485, and each submodule can accommodate 500m of sensing cable at maximum.
Stand-Alone System
LBMM-100, main display module can be directly connected with leak sensing cable without LBSM. It can accommodate 1,000m of sensing cable at max. In other hand, LBSM-200 or LBSM-300, the submodule can be used without LBMM. If necessary, it can be connected with Windows PC via RC-MBT for monitoring the status of leak sensing cable and for positioning the point where the leakage occurred.
Use
Power plant and sub-station
Water and various chemical detection around power generation plant, data centre, central command unit
Digital media centre
Water detection including floor surfaces, subfloors and equipment location
Semi-conductor, battery,
display panel (LCD/LED)
factory
Water, acid and base leakage detection around pipes, storage tanks, and trenches such as sulfuric acid, sulphurous acid, nitric acid, PAC and sodium hydroxide etc.
Army bases
Oil and chemical leak detection including pipes and storage tank
The LDS systems are intrinsically safe leak detection system is approved for installation in ordinary and hazardous areas when used with LBSC-1000 or LBSC-7000 sensing cable with safety barrier being stated in the Ex certificates. Protection Ex ia ⅡC T4 Ga Certificate No. BASEEFA 15Y0074, IECEx BAS15.0064X